For each mandatory Victorian rental safety check: the interval, who may perform it, what it covers, what must be recorded and given to the renter, and the regulation or Act provision that says so — read from the authorised Residential Tenancies Regulations 2021 (version 009) and the Consumer Affairs Victoria and Energy Safe Victoria pages listed as sources. English and Chinese rows; CC BY 4.0.

The register text and structure are original OptimaRea work under CC BY 4.0; the regulations and government pages it summarises retain their own terms. Cite the canonical guide URL.

https://creativecommons.org/licenses/by/4.0/

## Victorian rental safety checks register (electrical, gas, smoke alarm, pool barrier) (en)

### Electrical safety check

- **How often:** Every 2 years. If none was done in the 2 years before the renter moved in, "as soon as practicable". Since 13 October 2026 this applies to every rental agreement, whatever its start date.
- **Who may do it:** A licensed or registered electrician (Consumer Affairs Victoria: licensed with Energy Safe Victoria as a Registered Electrical Contractor).
- **What it covers:** All electrical installations, appliances and fittings the rental provider supplies, checked to section 4 of AS/NZS 3019. From 29 March 2023 every power outlet and lighting circuit must be protected by a switchboard-type circuit breaker and RCD.
- **What must be recorded / given to the renter:** Electrician’s name and licence or registration number, date, results including repairs required and actions taken, and a report under section 2 of AS/NZS 3019 (the Energy Safe check report or Form 1 — not a Certificate of Electrical Safety). Kept until the next record exists; copy to the renter within 7 days of a written request; date given in writing on request.
- **Rule:** Residential Tenancies Regulations 2021, Schedule 3 cl 1 and reg 30(2); RTA 1997 ss 27C, 68B

Sources:
- [Residential Tenancies Regulations 2021 (Vic), Schedule 3 — Safety-related activities (authorised version 009)](https://www.legislation.vic.gov.au/in-force/statutory-rules/residential-tenancies-regulations-2021/009)
- [Residential Tenancies Regulations 2021 (Vic), regulation 30 — Requirements for gas and electrical safety check record keeping](https://www.legislation.vic.gov.au/in-force/statutory-rules/residential-tenancies-regulations-2021/009)
- [Consumer Affairs Victoria — Rental providers: gas and electrical safety (page updated 14 October 2026)](https://www.consumer.vic.gov.au/housing/renting/repairs-alterations-safety-and-pets/gas-electrical-and-water-safety-standards/rental-providers-gas-and-electrical-safety)
- [Consumer Affairs Victoria — New changes to the rental laws (page updated 14 October 2026)](https://www.consumer.vic.gov.au/housing/renting/new-changes-to-rental-laws)
- [Energy Safe Victoria — Residential tenancy (electricians’ toolkit, reviewed 1 March 2024)](https://www.energysafe.vic.gov.au/industry-guidance/electrical/electricians-toolkit/residential-tenancy)

### Gas safety check

- **How often:** Every 2 years, only where the premises have appliances, fixtures or fittings that use or supply gas. Same "as soon as practicable" rule at move-in; since 13 October 2026 it applies to every rental agreement. A separate gas check within the prior 6 months is required before draught-proofing work.
- **Who may do it:** A licensed or registered gasfitter endorsed in Type A Gas Appliances Servicing on their Plumbers Identity Card.
- **What it covers:** All gas installations and fittings: LPG cylinders and components, appliance isolation valves, accessibility for servicing, electrical safety of the installation, clearances to combustibles, ventilation, flue and chimney condition, a leakage test and servicing of each Type A appliance to AS 4575.
- **What must be recorded / given to the renter:** Gasfitter’s name and licence or registration number, date, results including servicing and repairs, plus the Type A appliance record of work. Kept until the next record exists; copy to the renter within 7 days of a written request; date given in writing on request.
- **Rule:** Residential Tenancies Regulations 2021, Schedule 3 cl 2 and reg 30(1); RTA 1997 ss 27C, 68B

Sources:
- [Residential Tenancies Regulations 2021 (Vic), Schedule 3 — Safety-related activities (authorised version 009)](https://www.legislation.vic.gov.au/in-force/statutory-rules/residential-tenancies-regulations-2021/009)
- [Residential Tenancies Regulations 2021 (Vic), regulation 30 — Requirements for gas and electrical safety check record keeping](https://www.legislation.vic.gov.au/in-force/statutory-rules/residential-tenancies-regulations-2021/009)
- [Consumer Affairs Victoria — Rental providers: gas and electrical safety (page updated 14 October 2026)](https://www.consumer.vic.gov.au/housing/renting/repairs-alterations-safety-and-pets/gas-electrical-and-water-safety-standards/rental-providers-gas-and-electrical-safety)
- [Consumer Affairs Victoria — New changes to the rental laws (page updated 14 October 2026)](https://www.consumer.vic.gov.au/housing/renting/new-changes-to-rental-laws)
- [Energy Safe Victoria — Residential property safety checks (reviewed 28 May 2026)](https://www.energysafe.vic.gov.au/community-safety/energy-safety-guides/home-safety/tenants-and-renting-laws)

### Smoke alarm check

- **How often:** Tested at least once every 12 months in accordance with the manufacturer’s instructions, kept in working condition and fitted with batteries or replacement batteries. Since 25 November 2025 annual checks apply to every rental agreement.
- **Who may do it:** Testing and battery replacement on a battery alarm may be done by anyone; any testing, repair or replacement of a mains-powered (hard-wired) alarm must be done by a suitably qualified person, and a hard-wired alarm must be installed by a qualified electrician.
- **What it covers:** Every alarm in the premises. Alarms must meet AS 3786; buildings constructed after 1 August 1997 need hard-wired alarms with battery backup. A faulty alarm is an urgent repair: once notified, the rental provider must immediately arrange repair or replacement.
- **What must be recorded / given to the renter:** The date of the last smoke alarm test is an item on the prescribed rental agreement (Form 1, item 17). On or before the start of the agreement the renter must be given written information on how each alarm operates, how to test it, and the duty not to tamper and to report faults.
- **Rule:** Residential Tenancies Act 1997 s 68AA; prescribed agreement Form 1 cl 30A (Residential Tenancies Regulations 2021, Schedule 1)

Sources:
- [Residential Tenancies Regulations 2021 (Vic), Schedule 1, Form 1 — prescribed residential rental agreement, clause 30A (smoke alarms) and items 17–19](https://www.legislation.vic.gov.au/in-force/statutory-rules/residential-tenancies-regulations-2021/009)
- [Consumer Affairs Victoria — Smoke alarms and fire safety in rental properties (page updated 27 February 2026)](https://www.consumer.vic.gov.au/housing/renting/repairs-alterations-safety-and-pets/keeping-the-property-safe/smoke-alarms-and-fire-safety)
- [Consumer Affairs Victoria — New changes to the rental laws (page updated 14 October 2026)](https://www.consumer.vic.gov.au/housing/renting/new-changes-to-rental-laws)
- [Consumer Affairs Victoria — Repairs in rental properties (page updated 27 February 2026)](https://www.consumer.vic.gov.au/housing/renting/repairs-alterations-safety-and-pets/repairs/repairs-in-rental-properties)

### Swimming pool barrier

- **How often:** Maintained in good repair at all times; a barrier reported as not working must be repaired or replaced immediately as an urgent repair. The date of the most recent pool barrier compliance check must be disclosed before an agreement.
- **Who may do it:** Pool barrier compliance certificates are issued under the Building Act 1993 by a registered building surveyor or inspector; the rental provider must give the renter a copy of the most recent certificate on request.
- **What it covers:** Any swimming pool or spa on the premises capable of holding water deeper than 300 mm; a renter may not erect a relocatable pool without prior written notice and any required approvals.
- **What must be recorded / given to the renter:** Most recent certificate of pool barrier compliance; disclosure of its date before the agreement.
- **Rule:** Residential Tenancies Regulations 2021, Schedule 3 cll 4–5 and reg 16(2)(d); Building Act 1993

Sources:
- [Residential Tenancies Regulations 2021 (Vic), Schedule 3 — Safety-related activities (authorised version 009)](https://www.legislation.vic.gov.au/in-force/statutory-rules/residential-tenancies-regulations-2021/009)
- [Residential Tenancies Regulations 2021 (Vic), regulation 16(2)(d)–(e) — Information to be disclosed before a rental agreement](https://www.legislation.vic.gov.au/in-force/statutory-rules/residential-tenancies-regulations-2021/009)
- [Residential Tenancies Regulations 2021 (Vic), Schedule 1, Form 1 — prescribed residential rental agreement, clause 30A (smoke alarms) and items 17–19](https://www.legislation.vic.gov.au/in-force/statutory-rules/residential-tenancies-regulations-2021/009)

## 维州出租房安全检查登记表（电气、燃气、烟雾报警器、泳池围栏） (zh)

### 电气安全检查（electrical safety check）

- **频率:** 每 2 年一次。租客入住时若前 2 年内没有做过，须「尽快」安排。自 2026 年 10 月 13 日起适用于所有租约，不论签约日期。
- **谁可以做:** 持牌或注册电工（Consumer Affairs Victoria：须为 Energy Safe Victoria 登记的 Registered Electrical Contractor）。
- **检查范围:** 房东提供的全部电气装置、电器与配件，按 AS/NZS 3019 第 4 节检查。自 2023 年 3 月 29 日起，所有电源插座与照明回路须接入配电箱式断路器与漏电保护器（RCD）。
- **必须记录 / 提供给租客的内容:** 电工姓名与牌照/注册号、日期、结果（含需维修项目与处理情况），以及按 AS/NZS 3019 第 2 节出具的报告（Energy Safe 检查报告或 Form 1，不是 Certificate of Electrical Safety）。保存至下一次记录产生；租客书面要求后 7 天内提供副本；最近一次检查日期须应要求书面告知。
- **依据:** Residential Tenancies Regulations 2021 附表 3 第 1 条、第 30(2) 条；RTA 1997 第 27C、68B 条

来源:
- [Residential Tenancies Regulations 2021 (Vic), Schedule 3 — Safety-related activities (authorised version 009)](https://www.legislation.vic.gov.au/in-force/statutory-rules/residential-tenancies-regulations-2021/009)
- [Residential Tenancies Regulations 2021 (Vic), regulation 30 — Requirements for gas and electrical safety check record keeping](https://www.legislation.vic.gov.au/in-force/statutory-rules/residential-tenancies-regulations-2021/009)
- [Consumer Affairs Victoria — Rental providers: gas and electrical safety (page updated 14 October 2026)](https://www.consumer.vic.gov.au/housing/renting/repairs-alterations-safety-and-pets/gas-electrical-and-water-safety-standards/rental-providers-gas-and-electrical-safety)
- [Consumer Affairs Victoria — New changes to the rental laws (page updated 14 October 2026)](https://www.consumer.vic.gov.au/housing/renting/new-changes-to-rental-laws)
- [Energy Safe Victoria — Residential tenancy (electricians’ toolkit, reviewed 1 March 2024)](https://www.energysafe.vic.gov.au/industry-guidance/electrical/electricians-toolkit/residential-tenancy)

### 燃气安全检查（gas safety check）

- **频率:** 每 2 年一次，仅适用于有使用或供应燃气的电器、固定装置或配件的房屋。入住时同样适用「尽快」规则；自 2026 年 10 月 13 日起适用于所有租约。进行防风密封（draught-proofing）工程前，须有过去 6 个月内的燃气检查。
- **谁可以做:** 持牌或注册燃气工（gasfitter），且 Plumbers Identity Card 上须有 Type A Gas Appliances Servicing 资质。
- **检查范围:** 全部燃气装置与配件：LPG 气瓶及部件、电器隔离阀、可维修性、装置的电气安全、与可燃物的间距、通风、烟道与烟囱状况、泄漏测试，以及按 AS 4575 对每台 Type A 电器的保养。
- **必须记录 / 提供给租客的内容:** 燃气工姓名与牌照/注册号、日期、结果（含保养与维修），并附 Type A 电器的 record of work。保存至下一次记录产生；租客书面要求后 7 天内提供副本；最近一次检查日期须应要求书面告知。
- **依据:** Residential Tenancies Regulations 2021 附表 3 第 2 条、第 30(1) 条；RTA 1997 第 27C、68B 条

来源:
- [Residential Tenancies Regulations 2021 (Vic), Schedule 3 — Safety-related activities (authorised version 009)](https://www.legislation.vic.gov.au/in-force/statutory-rules/residential-tenancies-regulations-2021/009)
- [Residential Tenancies Regulations 2021 (Vic), regulation 30 — Requirements for gas and electrical safety check record keeping](https://www.legislation.vic.gov.au/in-force/statutory-rules/residential-tenancies-regulations-2021/009)
- [Consumer Affairs Victoria — Rental providers: gas and electrical safety (page updated 14 October 2026)](https://www.consumer.vic.gov.au/housing/renting/repairs-alterations-safety-and-pets/gas-electrical-and-water-safety-standards/rental-providers-gas-and-electrical-safety)
- [Consumer Affairs Victoria — New changes to the rental laws (page updated 14 October 2026)](https://www.consumer.vic.gov.au/housing/renting/new-changes-to-rental-laws)
- [Energy Safe Victoria — Residential property safety checks (reviewed 28 May 2026)](https://www.energysafe.vic.gov.au/community-safety/energy-safety-guides/home-safety/tenants-and-renting-laws)

### 烟雾报警器检查（smoke alarm check）

- **频率:** 按生产商说明至少每 12 个月测试一次，保持正常工作并装有电池或更换电池。自 2025 年 11 月 25 日起，年度检查适用于所有租约。
- **谁可以做:** 电池式报警器的测试与换电池任何人都可以做；接入市电（hard-wired）的报警器，其测试、维修或更换须由具备资质的人员进行，安装须由合格电工完成。
- **检查范围:** 房屋内的每一个报警器。须符合 AS 3786；1997 年 8 月 1 日后建成的房屋须使用带备用电池的市电报警器。报警器故障属于紧急维修：接到通知后房东须立即安排维修或更换。
- **必须记录 / 提供给租客的内容:** 最近一次烟雾报警器测试日期是法定租约（Form 1 第 17 项）的填写项。租约开始时或之前，须以书面形式告知租客每个报警器如何运作、如何测试，以及不得擅动并须报告故障的义务。
- **依据:** Residential Tenancies Act 1997 第 68AA 条；法定租约 Form 1 第 30A 条（Residential Tenancies Regulations 2021 附表 1）

来源:
- [Residential Tenancies Regulations 2021 (Vic), Schedule 1, Form 1 — prescribed residential rental agreement, clause 30A (smoke alarms) and items 17–19](https://www.legislation.vic.gov.au/in-force/statutory-rules/residential-tenancies-regulations-2021/009)
- [Consumer Affairs Victoria — Smoke alarms and fire safety in rental properties (page updated 27 February 2026)](https://www.consumer.vic.gov.au/housing/renting/repairs-alterations-safety-and-pets/keeping-the-property-safe/smoke-alarms-and-fire-safety)
- [Consumer Affairs Victoria — New changes to the rental laws (page updated 14 October 2026)](https://www.consumer.vic.gov.au/housing/renting/new-changes-to-rental-laws)
- [Consumer Affairs Victoria — Repairs in rental properties (page updated 27 February 2026)](https://www.consumer.vic.gov.au/housing/renting/repairs-alterations-safety-and-pets/repairs/repairs-in-rental-properties)

### 游泳池围栏（pool barrier）

- **频率:** 须随时保持良好状态；租客报告围栏失效后，须作为紧急维修立即修复或更换。签约前须披露最近一次围栏合规检查的日期。
- **谁可以做:** 围栏合规证书依 Building Act 1993 由注册建筑测量师或检查员出具；房东须应要求向租客提供最近一次证书副本。
- **检查范围:** 房屋内任何能蓄水深度超过 300 毫米的泳池或 spa；租客未事先书面通知并取得所需批准，不得架设可移动泳池。
- **必须记录 / 提供给租客的内容:** 最近一次泳池围栏合规证书；签约前披露其日期。
- **依据:** Residential Tenancies Regulations 2021 附表 3 第 4–5 条、第 16(2)(d) 条；Building Act 1993

来源:
- [Residential Tenancies Regulations 2021 (Vic), Schedule 3 — Safety-related activities (authorised version 009)](https://www.legislation.vic.gov.au/in-force/statutory-rules/residential-tenancies-regulations-2021/009)
- [Residential Tenancies Regulations 2021 (Vic), regulation 16(2)(d)–(e) — Information to be disclosed before a rental agreement](https://www.legislation.vic.gov.au/in-force/statutory-rules/residential-tenancies-regulations-2021/009)